This installation was on a 4-story home, and the tech had not yet gone to the basement to troubleshoot the “infinity” water source heat pump, as he was told he by the homeowner. He was in the attic at the infinity furnace above the 4th floor. He was getting his dcv in the proper range on his A and B green plug on the air handler, 3 to 4 vdc. His indoor board ohm reading was in range, 28k to 32 k. The tech ohmed out the A and B thermostat wires on the water source heat pump from the upstairs. His ohm reading was not in range of a normal infinity board. His reading was around 64.4k. The tech then made the long walk to the basement where the “geothermal heat pump” was located. Bingo.
December 21, 2022
Adaptive Heat
If you have a 2-stage performance furnace, you have a heat mode called adaptive heat. Adaptive heat can be controlled with a single stage thermostat on a 2 stage performance unit with a call for heat on W1. The furnace control CPU determines what stage (low or high stage heat) is required based on stored previous run time.


The furnace will start with either low or high heat. If the furnace starts in low heat, the CPU will determine the time before switching to high heat. The time is 0-16 minutes. After 16 minutes, high stage will come on and stay on for the remaining of the heat cycle.
This can be very useful if there are not enough thermostat wires for 2 stage heating or a simple single stage thermostat is needed. Having a 2-stage furnace controlled from a single stage thermostat is a handy feature to have.
Unlock the Full Potential
This installation was on a 4-story home, and the tech had not yet gone to the basement to troubleshoot the “infinity” water source heat pump, as he was told he by the homeowner. He was in the attic at the infinity furnace above the 4th floor. He was getting his dcv in the proper range on his A and B green plug on the air handler, 3 to 4 vdc. His indoor board ohm reading was in range, 28k to 32 k. The tech ohmed out the A and B thermostat wires on the water source heat pump from the upstairs. His ohm reading was not in range of a normal infinity board. His reading was around 64.4k. The tech then made the long walk to the basement where the “geothermal heat pump” was located. Bingo.
More to Explore
Heat Pump
Keep up with the latest HVAC news from Mingledorff’s Inc.